Tailored for emissions monitoring at the source and along fencelines
Key features
- Device suited for surface-based and channeled sources
- Gas and particle analysis and identification
- Signatures and fingerprints
- Odor identification and quantification in correlation with reference standards (EN 13725, ASTM 679)
Leading the market with the most advanced and accurate outdoor monitoring system
The WT1 Pro is expertly designed for outdoor environments, particularly industrial sites, that require advanced emission monitoring both at the fencelines and at the source, whether surface-based or channeled. It delivers precise quantification and identification of emissions, with odor analyses aligned with reference standards (EN 13725, ASTM 679). Featuring customizable capabilities, the WT1 Pro captures real-time data on physical, chemical, and perceptual parameters (gases, odors, particles, etc.).
The WT1 Pro offers continuous and simultaneous monitoring of a broad range of sensory parameters, tailored to meet the specific needs of your operations. Whether you oversee a wastewater treatment plant, a waste recovery facility, an airport, a port, a heavy or processing industry, or a construction site, the WT1 Pro is designed to meet your exact requirements.
When integrated with the EllonaSoft platform, the WT1 Pro provides real-time alerts that facilitate proactive and informed decision-making to enhance environmental management. It also supports the initiation of remediation actions, either via its API or through wired connections, ensuring a swift and effective response to emission challenges while strengthening risk management and operational compliance.
WT1 Pro configurationsTechnical specifications and
types of data analyzed by the WT1 Pro:
Native features
Temperature
Humidity
Atmospheric pressure
Optional sensors
Noise
Gas
Up to 6 electrochemical gas sensors and 2 optical gas sensors
Particles
Multiple options available
Odor
Quality / Intensity / 1 card with 4 MOX sensors
Discover the perfect synergy between our WT1 Pro product and the EllonaSoft analysis platform.
Designed by Ellona, expert in environmental technologies, this combination delivers the ultimate solution for sophisticated and intelligent emission monitoring.
Learn more about EllonaSoftA proven product across various sectors and applications
Sector-specific configuration examples
Construction sites
CO / NO / NO₂ / PM / noise / °C / %RH / hPa
Waste composting facility
NH₃ / H₂S / RSH / PM / Odors / °C / %RH / hPa
Wastewater treatment
NH₃ / H₂S / RSH / VOCs / Odors / °C / %RH / hPa
Ports
CO / NO / NO₂ / SO₂ / VOCs / Odors / Noise / °C / %RH / hPa
Airports
CO / NO / NO₂ / VOCs / Odors / Noise / °C / %RH / hPa
A product with numerous technical advantages
Human Sensory Digitization (HSD)
Combining physical and chemical data collection with human perceptions
Source fingerprinting
Identify pollution sources and investigate root causes
Odor recognition
Identification and quantification (ASTM 679 / EN 13725) using our extensive databases
Patented technology
High-quality electronics for optimal signal-to-noise ratio and LOD (Limit of Detection)
Real-time data
Continuous monitoring with data intervals every 10 seconds
Dynamic system
Independent air inlet/outlet channels for gas and particulate measurements
Multiple connectivity options
Wi-Fi, Ethernet, LTE-M/GPRS
Power capabilities
12V DC input, PoE, battery, and solar panel
Remote updates
Remote updates for embedded software, configuration, and maintenance
Triggering of remediation actions
Control processes via the 4-20mA input, the ON/OFF relay, or the API integrated with EllonaSoft.
Alerts & notifications
Indicators device status in 7 colors
Geolocalisation
Integrated GNSS (GPS/Galileo/Beidou/Glonass)
Compact design
Durable against chemical corrosion, harsh environmental conditions, and physical impacts
Real-time analysis
By transforming raw data into actionable insights, Ellona’s environmental intelligence platform provides enriched data, facilitating effective and impactful actions for businesses and communities
Identification
Ellona’s AI algorithms and databases not only measure odors and particles but also identify their specific types.
Emission model
Ellona provides dispersion modeling software that integrates weather data to simulate the impact of a site’s emissions on its surrounding environment.
Alerts & notifications
The Ellona platform enables you to set up a range of real-time alerts and automate the creation of insightful reports.
Automated remediation activation
This feature, integrated particularly with the WT1 Pro, allows for the automation of triggering third-party systems (such as sampling, misting, ventilation, etc.) through precise management of ON/OFF devices and 4-20 mA inputs, or via the API. This automation ensures a rapid and appropriate response in the event of a detected incident.
Feedback on human perception
Ellona’s solutions feature real-time feedback functionality, allowing individuals to report their environmental perceptions and refine the analysis algorithms accordingly.
- Features
- Accessories
- Resources
Integrated sensors
Optional sensors :
Sensor | Principle | ELLONA virtual sensor | Training |
---|---|---|---|
Odour Detection | Source baseline odour variation with an upper threshold limit at 5 IOU | “ELLONA distance” Anomaly detection OIIL: Odour Intensity Index Level in real time | Sampling? NO Inputs? Source variation observation or QR code |
Odour Intensity | Odour Quantification & EN 13725, ASTM 679 | “IOU: Instrumental Odour Unit in real time” | Sampling? Olfactometry Sample Inputs? QR code + Dynamic Olfactometry |
Source Identification | Source Fingerprinting | “Identification” Classifier & Trigger value | Sampling? Source Inputs? QR code + Dynamic Olfactometry |
Sensor | Measuring Range | Resolution | LOD | Typical Accuracy |
---|---|---|---|---|
PM1 | 0 to 1 000 µg/m³ | 1 µg/m³ | 0,5 µg/m³ | ±2 µg/m³ |
PM2.5 | 0 to 2 000 µg/m³ | 1 µg/m³ | 0,5 µg/m³ | ±3 µg/m³ |
PM10 | 0 to 10 000 µg/m³ | 1 µg/m³ | 0,5 µg/m³ | ±4 µg/m³ |
PM count | PM1, PM2.5, PM10 particules/m³ | 1 particule | – | Linearity error <5%, Repeatability error <3% |
Sensor | Sensor Type | Measuring Range | LOD | Resolution | Main Interferences |
---|---|---|---|---|---|
Alcohols | Electrochemical | 0 to 200 ppm | 0,009 ppm | 0,001 ppm | +1% CO, hydrocarbons |
CH₄ – NDIR | Optical sensors | 0 to 5% | 0,01% | 0,02% of FS range | Light hydrocarbons |
CH₂O (Formaldéhyde) | Electrochemical | 0 to 10 ppm | 0,002 ppm | 0,001 ppm | +3% H₂ ; +15% CO ; +50% Ethanol, organic solvents |
Cl₂ | Electrochemical | 0 to 20 ppm | 0,018 ppm | 0,006 ppm | 100% NO₂ ; -80% H₂S |
CO | Electrochemical | 0 to 1 000 ppm | 0,063 ppm | 0,001 ppm | +10% H₂; -2% NO₂ |
CO₂ – NDIR | Optical sensors | 400 to 10 000 ppm | ± 30 ppm | 1 ppm | |
EtO (Oxyde d’éthylène) | Electrochemical | 0 to 10 ppm | 0,005 ppm | 0,001 ppm | +30% H₂ ; +50% CO; +60% EtOH |
H₂ | Electrochemical | 0 to 2 000 ppm | 6 ppm | 2 ppm | NO<40%; C₂H₄<25% |
H₂ | Electrochemical | 0 to 4 000 ppm | 6 ppm | 2 ppm | +70% CO |
H₂ | Electrochemical | 0 to 40 000 ppm | 15 ppm | 5 ppm | +60% CO |
HCl (HBr) | Electrochemical | 0 to 100 ppm | 0,09 ppm | 0,03 ppm | +250% H₂S; -150% NO₂; -20% Cl₂ |
HCN | Electrochemical | 0 to 100 ppm | 0,129 ppm | 0,043 ppm | +300% H₂; -180% NO₂; -12% Cl₂; +10% SO₂ |
H₂0₂ (Peroxyde) | Electrochemical | 0 to 100 ppm | 0,1 ppm | 0,03 ppm | + 100% SO₂ |
H₂S | Electrochemical | 0 to 50 ppm | 0,003 ppm | 0,001 ppm | -30% NO₂ ; -25% Cl2 ; +10% SO₂ |
NH₃ | Electrochemical | 0 to 100 ppm | 0,09 ppm | 0,03 ppm | -20% SO₂ |
NO | Electrochemical | 0 to 250 ppm | 0,011 ppm | 0,001 ppm | +10% H₂S; +2% NO₂ ; + 3% SO₂ |
NO₂ | Electrochemical | 0 to 5 ppm | 0,003 ppm | 0,001 ppm | +10% H₂S; +2% NO₂ ; + 3% SO₂ |
NO₂ + O₃ | Electrochemical | 0 to 10 ppm | 0,003 ppm | 0,001 ppm | +100% Cl2 |
N₂O – NDIR | Optical sensors | 0 to 1 000 ppm | 50 ppm | 20 ppm | +10% CO₂ |
O₂ | Electrochemical | 0 to 30% | 0,1% | 0,1% | |
PH₃ | Electrochemical | 0 to 20 ppm | 0,009 ppm | 0,003 ppm | +20% H₂S; -30% NO₂; +25% SO₂; +50% SiH₄ |
RSH (Tertiobutyl Mercaptan) | Electrochemical | 0 to 14 ppm | 0,1 ppm | 0,03 ppm | |
SO₂ | Electrochemical | 0 to 50 ppm | 0,008 ppm | 0,001 ppm | 130% NO₂ : -60% Cl2 ; + 40% C2 H₄ |
COV (concentration) | PID | 0 to 10 ppm | 0,003 ppm | 0,001 ppm | non-specific detection of compounds having an IP < 10.6 eV |
Sensor | Measuring Range | LOD | Accuracy | Resolution |
---|---|---|---|---|
Noise | 30 to 120 dBA | / | 1 dBA | 0,1 dBA |
Sensor | Measuring Range | LOD | Accuracy | Resolution | Lifespan |
---|---|---|---|---|---|
Temperature | -40°C to +85°C | / | ±1°C | 0,1°C | 3-5 years |
Humidity | 0 to 100% HR | / | ±3% HR | 0,01% HR | 3-5 years |
Atmospheric pressure | 300 to 1 100 hPa | / | ±1 hPa | 0,1 hPa | 3-5 years |